Cindi Basic is an incinerating toilet that burns waste to ashes at around 550 degrees Celsius (1200 Fahrenheit). Like an oven, it uses a heating element to heat up the chamber. All moisture and liquids are evaporated and all solid waste together with the paper bag is incinerated to ashes. The time needed to reach 550 degrees depends on the amount of waste and liquids that is present in the chamber during the process. Only urine, solid waste and toilet paper may be incinerated.
Our incinerating toilets has the highest safety standards and are equipped with a number of safety features that are independent of each other. They are also equipped with a mechanical overheating protection that only can be reset manually – ensuring a safe and comfortable ownership.
When no programme is running, and the toilet is in standby mode, the fan constantly operates at low speed. The purpose of this is to let moisture ventilate out of the toilet and to prevent cold air from getting in to the toilet through the pipe. When an incineration programme is running, the fan draws air through the incineration chamber to constantly add oxygen to the incineration process. This also enables hot air and smoke to flow through the pipe and out of the chamber
IMPORTANT! As long as the toilet is attached to the ventilation pipe, the power should be turned on. When the fan spins, it prevents moist air from entering the toilet. If the power is turned off, the toilet should be disconnected from the pipe and the pipe plugged to prevent moist air from entering.